product range partners tech support case studies

 

TOSHIBA TOSVERT VFS-11 up to 15 kW

  • Latest drive available in this kilowatt range
  • Compact
  • Extends the features offered by previous drives
  • User friendly
  • Easy to program
  • Compact size
  • High ambient temperature withstand
  • Front mounted potentiometer
  • Commissioning is simple
  • Large range of adjustable parameters


The global standard inverters

  • The Tosvert VFS-11 meets major global standards: UL/CUL, CE and C-tick.

Wide input voltage range

  • Single three phase : from 200V to 240V
  • Three phase 200V class: from 200V to 230V
  • Three phase 400V class: from 380V to 500V

Switchable interface logic

  • The VFS-11 has a switchable control logic interface, a source logic (European type) or a sink logic (US/Japan type). It offers programmable terminal functions for assigning suitable functions to each terminal

EMI Noise filter inside

  • The three phase 400V class and single phase 200V class install EMI noise filters to meet EMC directive.

Features

  • A large potentiometer makes it simple for anyone to adjust output frequency
  • There are four automatic setting functions for easier operation. (Acceleration/deceleration time, V/f control mode, condition and terminal assignment)
  • The VFS11 allows side by side installation to minimise the space required
  • Sensorless vector control gives low speed start up torque of over 150% of the rated torque
  • The VFS11 detects inverter input and output phase failure

Options

  • Communication converter unit (RS485/RS232C)
  • Extended panel/parameter writer
  • IP43 enclosure/NEMA type 1 kits
  • DIN rail attachment (for 200V class 0.2 to 0.75kW)
  • Foot-mounted filter (EMC directive: For class B and class A)

Model Range- KW/HP

1 Phase 240V
 0.75-2.2KW

3 Phase 240V  
.75 -15KW  

3 Phase 460V .75-15KW

Voltage Rating

200-240V

200-240V

380-500V

Input Voltage Tolerance

 -10% / +10%

 -10% / +10%

 -10% / +10%

Voltage Regulation

Adjustable within the range of 50-600V by correcting the supply voltage (not adjustable above the input voltage)

PWM Carrier Frequency

Adjustable between 2.0KHz-16KHz. (default 12 KHz/current derate applies above 4KHz)


Control System

Sine Wave PWM System

V/Hz Pattern

Open Loop Vector, Constant Torque, Variable Torque, Auto Torque Boost, Manual Torque Boost, automatic energy saving, dynamic automatic energy saving, PM motor control, Auto Tuning, Base Frequency 25-500Hz, Torque Boost 0-30%; Start Frequency .5-10Hz

Overload Rating

150% for 60 seconds, 200% for .5 second

Frequency Setting

Potentiometer and Digital Input on Front Panel, Remote Potentiometer (1-10KOhms), 0-10Vdc (input impedance VIA/VIB=30KOhm), 4-20mAdc (input impedance 250 Ohm, 15 preset speeds by contact closure)

Frequency Precision

Analog Input ±0.5% of the Maximum Output Frequency, Digital Input ±0.01% of the Maximum Output Frequency

Frequency Command Resolution

0.01Hz Operation Panel, 0.1Hz Analog Input

Output Frequency Range

0.5-500Hz (default 0.5 -80Hz, maximum frequency 30-500Hz)

Frequency Jump

3 Frequencies with Adjustable Range

PID Control

Proportional Gain, Integral Gain and Differential Gain Settings and Control Wait Time

Upper and Lower Limit Frequencies

Upper Limit Frequency: 0 to max frequency, Lower Limit Frequency: 0 to upper limit frequency

Input Terminals

8 input terminals programmable to 65 functions. Logic selectable between sink and source.

Analog Inputs

(1) 4-20mA, (1) 0-10V or 1-10KOhm Potentiometer Connections

Output Contacts

1 Open Collector and 1 Relay contact programmable to 58 functions.

Analog Output

1mA / 7.5Vdc or switch selectable to 0-20mA (4-20mA), programmable to 19 functions

Power Terminals

Input (L1, L2, L3), Output (T1, T2, T3), DCL (PO, PA), DBR (PA, PB), DC BUS (PA, PC)

Protective Functions

Stall Prevention, Current Limitation, Output Short Circuit, Overvoltage, Overvoltage Limitation, Undervoltage, Ground Fault, Power Supply Phase Failure, Output Phase Failure, Overload Protection, Overcurrent at Startup, Overtorque, Undercurrent, Overheat, Cumulative Operation Time, Life Alarm, Emergency Stop, Braking Resistor Overload, Various Pre-alarms   

Retry

ASD can automatically clear fault upon trip. Programmable to 10 times with wait time up to 10 seconds between retry.

Restart

ASD will smoothly catch a freewheeling motor.

Ambient

Temperature: -10-50°C, Humidity 93% non-condensing

Installation

IP20 (enclosed type) /IP 54 available

LED Indications

Run, Monitor Mode, Program Mode, % and Hz Indication, Frequency Setting Mode by Potentiometer or Up/Down Keys, DC Bus Capacitors Charged

Monitoring

Operation Frequency, Operation Frequency Command, Forward/Reverse Run, Output Current, Voltage in DC Section, Output Voltage, Torque, Torque Current, Drive Load , DBR Load, Input Power, Output Power, Monitor of Input and Output Terminals, CPU and Memory Versions, PID Feedback and Frequency Command, Rated Current, Past Trips 1-4, Parts Replacement Alarm, Cumulative Run Time

Selectable Display Units

Current and voltage display selectable between Amps/Volts or % along with scaling factor multiplier.  

Download product information